Power System Protection & Switchgear

Design of Grounding Systems for Telecommunication Sites

Designing Earthing Systems for Telecommunication Sites

Duration 2 days Language English Venues 2 Scheduled dates 2

Scheduled Dates

DateVenueDeliveryFees
10 - 11 May 2027 Kuwait City - Kuwait Face-to-Face USD 1,995 per delegate Book
18 - 19 Aug 2027 Jakarta - Indonesia Face-to-Face USD 1,995 per delegate Book
DateVenueDeliveryFees
10 - 11 May 2027 Kuwait City - Kuwait Face-to-Face USD 1,995 per delegate Book
18 - 19 Aug 2027 Jakarta - Indonesia Face-to-Face USD 1,995 per delegate Book

No dates are currently scheduled for this delivery mode.

Course Introduction

Telecommunication site earthing has to serve three purposes at once — safety, lightning protection and equipment reference — and designs that satisfy one often compromise another. This course covers earthing design for towers, shelters and rooftop installations: soil resistivity and electrode design, bonding and equipotential arrangements, lightning protection integration, and the testing that verifies the installed system performs.

Course Highlights

Design earthing that serves safety, lightning and reference needs

Measure soil resistivity and design electrodes accordingly

Build bonding and equipotential arrangements correctly

Integrate lightning protection without creating problems

Test and verify installed earthing systems

Course Objectives

Describe earthing functions and their sometimes conflicting requirements

Measure and interpret soil resistivity

Design earth electrode systems and calculate resistance

Design bonding, equipotential and internal earthing

Integrate lightning protection and surge protection

Test, verify and maintain earthing systems

Training Methodology

The course is delivered through short instructor-led inputs followed immediately by applied practice. Participants work on structured exercises, worked examples and case material drawn from real situations, with facilitated discussion throughout. Delegates are encouraged to bring their own data, documents or scenarios, and time is set aside each day to apply the material to their own organisation.

Organisational Impact

Sites that meet safety and equipment protection requirements

Fewer lightning-related equipment failures

Designs verified by measurement

Consistent practice across site builds

Personal Impact

Specialist earthing design capability

Measurement and testing skill

Understanding of lightning protection integration

Stronger telecom infrastructure standing

Who Should Attend

Telecommunication infrastructure engineers

Electrical designers for telecom sites

Site build and installation contractors

Maintenance and field engineers

Testing and commissioning staff

Course Outline

Principles and Soil

Training hours 10 hours  ·  09:00 - 14:30 (venue local time), with refreshment breaks and a working lunch

Earthing functions: safety, lightning, reference

Standards and requirements for telecom sites

Soil resistivity measurement and interpretation

Electrode types and configurations

Practical: resistivity measurement

Design and Integration

Training hours 10 hours  ·  09:00 - 14:30 (venue local time), with refreshment breaks and a working lunch

Electrode system design and resistance calculation

Bonding, equipotential and internal earthing

Tower, shelter and rooftop arrangements

Lightning protection and surge protection integration

Testing, verification and maintenance

Workshop: designing a site earthing system

Certificate

Delegates who complete the programme receive a MAWA Events Certificate of Attendance, recording the course title, dates, venue and training hours completed.

From USD 1,995
Register

Search for a Course by Keywords