Power Systems Protection – Fundamentals & Advanced
Power Systems Protection From Fundamentals to Advanced Practice
Scheduled Dates
| Date | Venue | Delivery | Fees | |
|---|---|---|---|---|
| 30 Aug - 03 Sep 2027 | Jakarta - Indonesia | Face-to-Face | USD 3,895 per delegate | Book |
| 07 - 11 Nov 2027 | Manama - Bahrain | Face-to-Face | USD 3,895 per delegate | Book |
| Date | Venue | Delivery | Fees | |
|---|---|---|---|---|
| 30 Aug - 03 Sep 2027 | Jakarta - Indonesia | Face-to-Face | USD 3,895 per delegate | Book |
| 07 - 11 Nov 2027 | Manama - Bahrain | Face-to-Face | USD 3,895 per delegate | Book |
No dates are currently scheduled for this delivery mode.
Course Introduction
Protection errors fall into two groups: schemes that fail to operate and schemes that operate when they should not, and both usually originate in settings and coordination rather than relay hardware. This five-day course runs from fundamentals through to advanced application — fault calculation, relay characteristics and settings, coordination, unit and distance protection, and testing and commissioning.
Course Highlights
Calculate faults well enough to set protection properly
Select relay characteristics and calculate settings
Coordinate protection across the system
Apply differential, distance and busbar protection
Test and commission schemes to verify operation
Course Objectives
Calculate symmetrical and asymmetrical fault currents
Describe CT and VT characteristics, selection and limitations
Select relay types and calculate overcurrent and earth fault settings
Coordinate protection and verify grading
Apply differential, distance, busbar and generator protection
Test, commission and troubleshoot protection schemes
Training Methodology
The course is delivered through short instructor-led inputs followed immediately by applied practice. Participants work on structured exercises, worked examples and case material drawn from real situations, with facilitated discussion throughout. Delegates are encouraged to bring their own data, documents or scenarios, and time is set aside each day to apply the material to their own organisation.
Organisational Impact
Protection that operates correctly and selectively
Nuisance tripping reduced
Settings calculated and documented
Schemes verified by testing
Personal Impact
Complete protection capability from fundamentals up
Setting calculation and coordination skill
Testing and commissioning competence
Strong positioning in protection engineering
Who Should Attend
Protection and control engineers
Electrical engineers and senior technicians
Testing and commissioning personnel
Substation and plant electrical staff
Consultants and contractors in protection
Course Outline
Fundamentals and Fault Calculation
Protection objectives, zones and requirements
Symmetrical components and fault types
Fault current calculation methods
System earthing and its protection consequences
Practical: fault calculation exercises
Instrument Transformers and Relays
CT and VT construction, classes and selection
CT saturation, burden and knee point
Relay types, characteristics and technology
Relay inputs, outputs and logic
Practical: CT selection and relay familiarisation
Overcurrent and Earth Fault Protection
Overcurrent characteristics and setting calculation
Earth fault protection and sensitivity
Directional protection and its application
Coordination and grading verification
Practical: setting calculation and grading
Unit and Distance Protection
Differential protection: transformer, feeder, busbar
Distance protection zones and settings
Teleprotection and schemes
Generator and motor protection
Practical: differential and distance settings
Testing and Commissioning
Secondary injection testing methods
Primary injection and CT testing
Scheme functional and end-to-end testing
Commissioning records and documentation
Practical: relay testing exercises
Certificate
Delegates who complete the programme receive a MAWA Events Certificate of Attendance, recording the course title, dates, venue and training hours completed.