Protection Relay Systems – Configuration, Testing & Troubleshooting
Configuring, Testing and Troubleshooting Protection Relays
Scheduled Dates
| Date | Venue | Delivery | Fees | |
|---|---|---|---|---|
| 15 - 17 Feb 2027 | Singapore - Singapore | Face-to-Face | USD 2,495 per delegate | Book |
| 09 - 11 May 2027 | Jeddah - Saudi Arabia | Face-to-Face | USD 2,495 per delegate | Book |
| Date | Venue | Delivery | Fees | |
|---|---|---|---|---|
| 15 - 17 Feb 2027 | Singapore - Singapore | Face-to-Face | USD 2,495 per delegate | Book |
| 09 - 11 May 2027 | Jeddah - Saudi Arabia | Face-to-Face | USD 2,495 per delegate | Book |
No dates are currently scheduled for this delivery mode.
Course Introduction
Protection settings are calculated once and then live for decades through network changes nobody fed back into the study. Misoperation and failure to operate both trace back to that gap, along with testing that proves the relay works but not that the scheme does. This course covers protection relay work end to end: principles and scheme design, setting calculation, configuration and communications, secondary injection testing, and diagnosing misoperation from event records.
Course Highlights
Calculate and apply protection settings correctly
Configure modern numerical relays and their communications
Carry out secondary injection testing properly
Diagnose misoperation from relay event records
Maintain coordination as the network changes
Course Objectives
Describe protection principles and common scheme types
Calculate settings for overcurrent, earth fault, differential and distance protection
Configure numerical relays including logic and communications
Plan and execute secondary injection test procedures
Analyse disturbance records and event logs
Review coordination following network modification
Training Methodology
The course is delivered through short instructor-led inputs followed immediately by applied practice. Participants work on structured exercises, worked examples and case material drawn from real situations, with facilitated discussion throughout. Delegates are encouraged to bring their own data, documents or scenarios, and time is set aside each day to apply the material to their own organisation.
Organisational Impact
Protection that operates correctly and discriminates
Fewer unnecessary outages from misoperation
Test evidence that supports compliance
Settings reviewed when the network changes
Faster diagnosis after protection events
Personal Impact
Command of protection setting and testing practice
Confidence with numerical relay configuration
Diagnostic capability using event records
Stronger standing in power system work
Positioning for protection engineering roles
Who Should Attend
Protection and control engineers
Electrical engineers and senior technicians
Commissioning and testing personnel
Substation maintenance staff
Utility and industrial power system engineers
Course Outline
Principles and Schemes
Protection philosophy, zones and grading
Instrument transformers and their limitations
Overcurrent, earth fault and directional protection
Differential and distance protection schemes
Workshop: scheme selection for a network
Settings and Configuration
Fault calculation inputs to settings
Setting calculation and coordination
Numerical relay configuration and logic
Communications, GOOSE and interoperability
Workshop: calculating and entering settings
Testing and Diagnosis
Secondary injection testing methods
Scheme testing versus relay testing
Commissioning records and documentation
Analysing disturbance records and misoperation
Practical: injection testing and fault analysis
Certificate
Delegates who complete the programme receive a MAWA Events Certificate of Attendance, recording the course title, dates, venue and training hours completed.