Electrical Installations in Hazardous Locations
Designing, Installing and Inspecting Electrical Systems in Explosive Atmospheres
Scheduled Dates
| Date | Venue | Delivery | Fees | |
|---|---|---|---|---|
| 11 - 13 Jan 2027 | Hong Kong - Hong Kong | Face-to-Face | USD 2,495 per delegate | Book |
| 17 - 19 Oct 2027 | Muscat - Oman | Face-to-Face | USD 2,495 per delegate | Book |
| Date | Venue | Delivery | Fees | |
|---|---|---|---|---|
| 11 - 13 Jan 2027 | Hong Kong - Hong Kong | Face-to-Face | USD 2,495 per delegate | Book |
| 17 - 19 Oct 2027 | Muscat - Oman | Face-to-Face | USD 2,495 per delegate | Book |
No dates are currently scheduled for this delivery mode.
Course Introduction
In a hazardous area, an electrical installation that is merely compliant on paper can still ignite an atmosphere. Protection concepts have to match the zone, equipment selection has to match the gas or dust group, and installation detail — glanding, sealing, earthing, maintenance records — decides whether the protection actually holds. This course covers area classification, protection concepts, equipment selection and the inspection regime, aligned to the IEC 60079 series.
Course Highlights
Interpret area classification drawings and zone boundaries
Match protection concepts to zone, gas group and temperature class
Select and verify Ex equipment and its certification
Install, gland and seal correctly for each protection type
Run the initial, periodic and sample inspection regime
Course Objectives
Explain ignition mechanisms and the basis of area classification
Read and apply hazardous area classification documentation
Select equipment appropriate to zone, group and temperature class
Apply installation requirements for Ex d, Ex e, Ex i and Ex p
Carry out inspections to the required grades and document them
Manage modification, repair and continued conformity
Training Methodology
The course is delivered through short instructor-led inputs followed immediately by applied practice. Participants work on structured exercises, worked examples and case material drawn from real situations, with facilitated discussion throughout. Delegates are encouraged to bring their own data, documents or scenarios, and time is set aside each day to apply the material to their own organisation.
Organisational Impact
Installations that remain compliant through their life
Inspection records that satisfy auditors and insurers
Fewer unsafe modifications and informal repairs
Competent selection reducing procurement errors
Demonstrable alignment with IEC 60079 practice
Personal Impact
Practical command of hazardous area requirements
Confidence selecting and verifying Ex equipment
Inspection capability to a defined standard
Understanding of why each detail matters
Stronger standing in safety-critical electrical work
Who Should Attend
Electrical engineers and technicians in process industries
Maintenance and inspection personnel
HSE and technical safety professionals
Project and commissioning engineers
Contractors working on hazardous area installations
Course Outline
Classification and Concepts
Ignition mechanisms and explosive atmospheres
Area classification: zones, gas groups, temperature classes
Protection concepts and where each is used
Certification, marking and documentation
Workshop: reading classification drawings
Equipment and Installation
Equipment selection for zone and group
Ex d, Ex e, Ex i and Ex p installation requirements
Glanding, sealing, cable and earthing practice
Intrinsically safe systems and loop verification
Workshop: assessing installation photographs
Inspection, Maintenance and Conformity
Initial, periodic and sample inspection grades
Inspection schedules and documentation
Repair, overhaul and modification control
Common findings and their root causes
Workshop: conducting a detailed inspection
Certificate
Delegates who complete the programme receive a MAWA Events Certificate of Attendance, recording the course title, dates, venue and training hours completed.